Conductors: Class C, soft drawn, bare copper per ASTM B3 and ASTM B8. Insulation: Heat and moisture resistant, polyvinyl chloride meeting the requirements of UL 83 for Type THHN and THWN wires. The insulation is acceptable for use in locations at 90°C dry or 75°C wet. The insulation thickness is in accordance with UL 83. Conductor Jacket: A nylon jacket is applied directly to the surface of the PVC insulation. Nylon shall meet the requirements of UL 83. The thickness is in accordance with UL 83. Ground Conductor: Class C, soft drawn, bare copper per ASTM B3 and ASTM B8. The conductor is insulated with PVC/Nylon and the nominal overall diameter shall equal the insulated circuit conductors. Assembly: The insulated circuit and grounding conductors are laid flat and parallel together. The jacket will be applied directly over the insulated conductors encapsulating them. Jacket: Heat and moisture resistant, Black polyvinyl chloride meeting the requirements of UL 83. The thickness is in accordance with UL 83. Color Code: Black, yellow, red & green grounding conductor. Surface Marking: The overall jacket will have the following information printed: PAIGE SUBMERSIBLE PUMP CABLE NUMBER AND “size of conductors”, TYPE THHN/THWN 600 V (UL). Approvals: UL: E63611-T MSHA: P-7K-206644
Heavy duty (double jacketed), Flat Submersible pump cable suitable for use within well casings for wiring deep well fresh or salt water submersible pumps.
Paige has earned ISO 9001:2015 certification for its factories in Columbus, NE and Silao, Mexico. We are dedicated to ensuring customer satisfaction and continual improvement, while embracing sustainability practices.